Furnaces of the big dimensions, as a rule, heat two or three rooms. All such
furnaces, without an exception, while translating it is necessary to divide into
gas on two independent sections, and each section to convert as the separate furnace.
By preparation for re-equipment by external examination survey a furnace and chimney
laying. If the furnace laying shabby the furnace should be disassembled and on
its place to lay out two new furnaces specially intended for burning of gas. At
a satisfactory condition of a laying flues are altered only. Peter tells me about search domains directory . xmas dresses 2009 . packshots Re-equipment of the furnace begin with dismantling of one of lateral walls
of a laying. Then take out a grid-iron lattice, top internal. From the furnace
delete partitions between, and also a laying зольника and full tankа, not connected
with external furnaces.
In the
furnace spread the brick wall dividing into two independent sections. To height
of 10th number from the basis the wall is spread from a fire-resistant brick,
and by other numbers before overlapping of the furnace from the red. A thickness
of a wall 120 or 2130 - silt. In each of two formed sections spread and full tank.
The size full tankов should be not less than 0,04 м3 (length 0,4, width 0,25,
height 0,4). Full tank it is necessary to spread so that the bottom zone of the
furnace intensively got warm. Then establish regulators of secondary air and a
framework for torches. Frameworks are desirable for placing from corridors. The
general теплоотдача furnaces (at two fire chambers a day) 3850 kcal/ch. Buy Cigarettes online . Registrar bono de bienvenida alla Flues in the isolated sections can be carried out direct-flow (as furnaces)
or the consecutive vertical. At the calculation new дымооборотов it is necessary
to arrange "cleanings" necessarily. In each isolated section establish
a latch. On one-two number above a latch establish hermetic door. In the chimney
basis do рассечку. The Chimney should have cross-section section 250х130 mm. Should
be laid out according to operation requirements. After the termination of installation works it is necessary to dry both sections
of the furnace and to check up tightness of a laying of the furnace and a chimney.
It is necessary to establish also gas torches in full tankах. On the same method
it is possible to convert and two-storeyed furnaces. In this case the furnace
on each floor break on two independent sections.
|